The development of modern technology has led to the emergence of new color sources with a different spectrum. Previously, light sources with incandescent filaments were used, then fluorescent lamps, which already had an uneven spectrum of light, became widespread. Each of the species had its advantages and disadvantages. We test LED table lamps that provide high-quality lighting and are free from flaws.
Declared Specifications
Samples of Flora and Orion are represented by the Remez trademark from LLC Romati, which is a representative of the German manufacturer Remilicht GmBH. They use South Korean Sunlike LEDs, which provide lighting that is as close as possible to natural sunlight in the spectrum, safe for sight, does not violate the hormonal background and has a high color rendering index.
Parameter | Orion | Flora |
Power | 10W | 8W |
Light flow | 500lm | 470lm |
Colour temperature | 2700K - 6500K | 2700K - 6500K |
Dimensions | 441 x 486 x 200 mm. | 465 x 480 x 130 mm. |
Weight | 1.30 kg. | 0.97 kg. |
CRI color rendering index | > 95 | > 95 |
Warranty | 2 years | 2 years |
Power is supplied from an external power supply, this made it possible to minimize the size of LED desktop lamps and place the high-voltage part away from the table. If a child spills water when painting with paints, there will be no dangerous high voltage on the wetted surface.
Orion lamp design
The Orion LED lamp has many position settings due to 4 movable elements. The angle of inclination of the element in which the LEDs are located also changes. Due to this, you will get sufficient lighting at the required angle in any position. On the back wall there is a USB socket for a 5 Volt 1 Amp charger.
Flora design
The Flora table lamp has a base in the form of a flower pot in which stationery can be placed. The large green stem of the LED mount is fully flexible and movable. A small translucent sheet works as a night lamp. At the base of the sheet is an LED that illuminates the sheet from the inside.
Illumination
Samples are heated for 1 hour until the parameters stabilize. We measure the illumination on the desktop at minimum and maximum brightness using a light meter.
According to the standards, the level of illumination of the workplace should be at least 300 lux. This indicator relates to the performance of minor works, reading, drawing and other types.
Level | Orion | Flora |
Minimum Suite | 610lx | 520lx |
Maximum, lux | 1320lx | 970lx |
The measurement results showed a maximum illumination of up to 1320 and 970 lux, respectively, which is enough for any precise work.
Unlike conventional luminaires
These models of LED table lamps combine the advantages of various light sources that conventional lamps do not have:
- high color rendering index CRI> 95, like incandescent lamps;
- low power consumption of 8-10W, like fluorescent bulbs;
- smooth change in color temperature, from incandescent to luminescent;
- compact dimensions, like LED lighting sources;
- design is combined with the versatility of the design.
Spectrum
A study of the spectrum of conventional LED and fluorescent lamps revealed an effect on human vision and condition. In ordinary LEDs, there is a large amount of blue at a wavelength of 450 nm, which does not allow the pupil to narrow normally. The pupil passes a lot of blue light, which accelerates the deterioration of vision. A large amount of blue light reduces the production of sleep hormone melatonin, which can weaken the immune system and affect other processes.
The Orion and Flora table lamps use the new Korean Sunlike LEDs, which have an even spectrum and are devoid of a large peak of blue light. The light is obtained as close as possible to natural sunlight in the spectrum.
Many smartphones already have night mode and reading mode, which are used when there is no external lighting, the smartphone screen becomes the only light source. In these modes, the radiation in the blue spectrum is reduced, the hue of the image is shifted to the warm part of the spectrum.
Colour temperature
One of the advantages of Orion and Flora LED table lamps is the ability to continuously adjust the color temperature. When turned on, it shines neutrally with white light at 4300K, the hue smoothly changes with two touch buttons. The measured adjustment range was from 2700K to 6700K, which corresponds to warm and cold white light. This will create a comfortable workplace lighting depending on your preferences.
Color rendering index
A high color rendering index provides accurate color reproduction and contrast, which is especially necessary when reading and working with documents. According to the measurement results, the color rendering is within the CRI 93-97, which is an excellent result.
For conventional LED light sources, the color rendering index is CRI 70-80, when the standard requires a minimum of CRI80 for residential premises. For reading and accurate work, CRI90 and above is required. Most often, manufacturers save and install the cheapest LEDs with CRI70, although CRI80 is indicated in the specifications.
Instruction manual
Where can I buy
You can buy tested LED table lamps at the indicated links or in other online stores:
Summary
The tested models provide the best lighting compared to other light sources, which in spectrum is similar to natural sunlight. CRI Flora and Orion LED luminaires with a high color rendering index can be a good present for students and seniors. The sooner you start taking care of your vision, the longer you keep it.
Author: Sergey Kazantsev
Samples tested in the laboratory, official website led-obzor.ru