ããŒãããŒãšé¡§å®¢åãã®å¹Žæ¬¡äŒè°ã§ãNetApp Insightã¯ONTAPãªãã¬ãŒãã£ã³ã°ã·ã¹ãã ãå®è¡ããæ°ããã¹ãã¬ãŒãžã·ã¹ãã ã®ãªãªãŒã¹ãçºè¡šããŸããã FASããã³AFFã·ã¹ãã ãæŽæ°ããŸããã
æ°ããæ©åšã®ãªãªãŒã¹ãšãšãã«ãONTAP 9.1ã®æ°ããããŒãžã§ã³ãå©çšå¯èœã«ãªããŸãã
ãŸããããŒããŠã§ã¢ã®æ°æ©èœãç解ããŸãããã
FASã ãã¹ãŠã®FlashCacheã 40GbEããã³32Gb FCãåããæåã®ã¹ãã¬ãŒãžã·ã¹ãã
FASãã€ããªããã¢ã¬ã€ãæŽæ°ããããšããå§ããŸãããã 4ã€ã®æ°ããã¢ãã«ããããŸããFAS2620ãFAS2650-ãšã³ããªãŒã¬ãã«ã·ã¹ãã ãFAS8200-æ³äººé¡§å®¢åããããã¬ã³ãžã·ã¹ãã ãFAS9000-ã·ã£ãŒã·ãæ§ç¯ãããŸã£ããæ°ããïŒ NetAppçšïŒã¢ãããŒããåãããã€ãšã³ãã·ã¹ãã ã§ãã
æ°ããã·ã¹ãã ã®çç£æ§ãå€§å¹ ã«åäžããŸããã
- Intelã®æ°ããBroadwellããã»ããµã䜿çš
- ããå€ãã®ãã£ãã·ã¥ãšNVRAMãå©çšå¯èœ
- NVMe FlashCache
- å€ãã³ã³ãããŒã©ãŒã§ã¯ã40GbEããã³32Gb FCã€ã³ã¿ãŒãã§ãŒã¹ãå©çšå¯èœã§ã
- SAS-3 12Gbã¯ãã©ã€ãã®æ¥ç¶ã«äœ¿çšãããŸã
ã芧ã®ãšãããã¢ãã«ã®æ°ã¯å°ãªããªããŸããããã¯ãæ°Žå¹³æ¹åã®ã¹ã±ãŒãªã³ã°ãå¯èœãªå Žåã¯éåžžã«è«ççã§ãã FAS8200ãèŠéããFAS9000ã®çç£æ§ãé«ããããšæãããã客æ§ã¯ãFAS8200ãã4ã³ã³ãããŒã©ãŒã®ã¯ã©ã¹ã¿ãŒãéžæã§ããŸãã
FAS2600
äžã®è¡ã«ã¯2ã€ã®ã¢ãã«ããããŸãã FAS2620ã¯FAS2554ã眮ãæããFAS2650ã¯FAS2552ã眮ãæããŸãã åæ§ã®åãæšãŠãããæ©èœã®ã¢ãã«FAS2520ã¯ãããŸããã ããã¯éåžžã«çã«ããªã£ãŠããŸããç§ã®ç·Žç¿ã§ã¯ããããã®ã¢ãã«ã¯ãã£ãã«è²©å£²ãããŸããã§ããã
FAS2620ãšFAS2650ã¯ãåäžä»£ãšåæ§ã«ãåãã³ã³ãããŒã©ãŒã䜿çšããŸãã ã·ã£ãŒã·ã®ã¿ãç°ãªããŸãã æåã®ã±ãŒã¹ã§ã¯ã24å°ã®SASãŸãã¯SSDãã©ã€ããåããã·ã£ãŒã·ã§ãã ãŸããFAS2620ã«ã¯12åã®SATAãŸãã¯SSDãã©ã€ããåããã·ã£ãŒã·ããããŸãã
ãããã®ã·ã¹ãã ã¯äž¡æ¹ãšããå€ãã¢ãã«ã«ã¢ããã°ã¬ãŒãããå Žåã«æ°ããã³ã³ãããŒã©ãŒã«æ¥ç¶ããããã«ãã£ã¹ã¯ã·ã§ã«ãã«å€æãããŸãã çŸåšãæ£ã ããDS224Cããã³DS212Cã§ãã ãããã¯ã12Gb SASã€ã³ã¿ãŒãã§ã€ã¹ãåããã·ã§ã«ãã§ãã åœåã®ååã¯åããŸãŸã§ã-ãã£ã¹ã¯ã·ã§ã«ãããŠãããæ°ããã£ã¹ã¯æ°ãã€ã³ã¿ãŒãã§ã€ã¹é床ã C-12ãã16é²æ°ã å¿ èŠã«å¿ããŠãæ°ããã·ã§ã«ããçŸåšã®FAS8000ã³ã³ãããŒã©ãŒã«æ¥ç¶ã§ããŸãã é©åãªSAS HBAãè³Œå ¥ããã ãã§ãã æ°ããã·ã§ã«ãã§ã¯ãACPã¯åå¥ã®ããŒããå¿ èŠãšãããSASå ã§åäœããŸãã
æ°ããã·ã¹ãã ã¯ãFAS2500äžä»£ã®3åã®é床ãçŽæããŸãã
- Intel Broadwellãã€ã¯ãã¢ãŒããã¯ãã£ã«åºã¥ã2ã€ã®6ã³ã¢ããã»ããµ
- 64GB DDR4ã¡ã¢ãª
- 8GB NVRAM
- 1TB NVMe M.2 FlashCache
ã¯ããã¯ããã¯ãïŒ ããè¥ãã¢ãã«ãNVMeãããã³åºæ¬æ§æã®FlashCacheã
FlashPoolããã³FlashCacheããŒã¹ã®ã³ã³ãããŒã©ãŒã®åèšãã£ãã·ã¥ã®æ倧å¶éã¯24TiBã«å¢å ããŸããã
æåŸã«ãã¯ã©ã¹ã¿ãŒçžäºæ¥ç¶å°çšã®10GbEããŒãããããŸãã ãŸããiSCSI / NFS / CIFS / FCoE + FCæ§æãååŸããããã«äœããç ç²ã«ããå¿ èŠã¯ãããŸããã
çŸåšãé»åæ倱ãçºçããå Žåã®NMRAMã®å 容ã¯æå·åãããèµ·åå¯èœãªUSBãã©ãã·ã¥ãã©ã€ãã«æžã蟌ãŸããŸãã
埮åŠãªéãïŒFAS2620ã¯all-SSDã®æ§æã§ã¯äœ¿çšã§ããŸããã æäœ8ã€ã®SATAãã©ã€ããå¿ èŠã§ãã FAS2650ã«ã¯ãã®ãããªå¶éã¯ãããŸããã
FAS8200
FAS8200ã¯ãçŸåšã®äžä»£ã®2ã€ã®ã¢ãã«ãFAS8020ãšFAS8040ãããã«çœ®ãæããŸããã FAS8200ã³ã³ãããŒã©ãŒã®ãã¢ã¯1ã€ã®ã±ãŒã¹ã«ããã3Uã®ã¿ãå æããŸãã ãã®ã·ã£ãŒã·ã«ã¯ãã£ã¹ã¯ããããŸããã FAS8040ãšæ¯èŒããŠãããã©ãŒãã³ã¹ãçŽ50ïŒ åäžãããšçŽæããŠããŸãã
- 2å以äžã®ã³ã¢
- 4åã®ã¡ã¢ãª
- 4TiBã«æ¡åŒµå¯èœãªããŒã¿ããŒã¹å ã®2 TiB NVMe FlashCache
ãããŠãç§ãã¡ã¯äœãæã£ãŠããŸããïŒ ã³ã³ãããŒã©ãŒã¯ãã匷åã§ãã¹ããŒã¹ãåããŸããã ãã ããã³ã³ãããŒã©ãŒã®æ¡åŒµã¹ãããã®æ°ã¯å°ãªãããµããŒããããã©ã€ãã®æ°ãå°ãªããªããŸãã ããããããã»ã©æªãã¯ãããŸããã
æåã«ãã£ã¹ã¯ãæ±ããŸãããã
çµ±èšã«ãããšãFAS8040ã®å£²ãäžãã®80ïŒ
以äžã¯150å°æªæºã®ãã©ã€ãã§çºçããŠããŸããã€ãŸããFAS8200ã®å¯Ÿè±¡ãŠãŒã¶ãŒã¯720å°ã®ãã©ã€ãããµããŒãããå¿
èŠããŸã£ãããããŸããã 480å°ã®ãã£ã¹ã¯ã®å¶éã誰ããæ©ãŸããŠããå Žåã¯ããã€ã§ãã¯ã©ã¹ã¿ãŒã«ã³ã³ãããŒã©ãŒãè¿œå ã§ãããã£ã¹ã¯ã®æ倧æ°ã¯960ã«å¢ããŸãã
å°ãªãæ¡åŒµã¹ãããã§äœãããŸããïŒ 8040ã®æ¡åŒµã¹ãããã¯ãå€ãã®å ŽåãFlashCacheã®äžã§äœ¿çšãããŸããFlashCacheã¯ãFAS8200ã®ãã¶ãŒããŒãäžã«ãããã¹ãããã¯äžèŠã§ãã NVRAMããªã¢ãŒããµã€ãã«ãã©ãŒãªã³ã°ãããFC-VIããŒãçšã®MetroClusterãæ§ç¯ããå Žåãè¿œå ã®ã¹ããããå¿ èŠã§ãã ããã§ããããã®ç®çã®ããã«ããã§ã«ã³ã³ãããŒã©ãŒã«ããUTA2ããŒãã䜿çšã§ããŸãã 480ãã©ã€ãããµããŒããããŠãããããSAS HBAã«ãŒããå æããå¿ èŠã¯ãããŸããã
ã³ã³ãããŒã©ã«ååãªåºæ¬ããŒãããªãå Žåãã¹ãããã¯ã€ãŒãµããããŸãã¯FCããŒãã«ã®ã¿å¿ èŠã§ããããšãããããŸãã ãããŠããã§ãNetAppãONTAP 9.1ã§40GbEããã³32Gb FCããŒãã®äœ¿çšããµããŒãããããã«ãªã£ãããšãæãåºããŠãã ããã 40GbEããŒãã¯ã4ã10GbEãšããŠäœ¿çšã§ããŸãã 40GbEããŒãã¯æ°ããã³ã³ãããŒã©ãŒã§ã®ã¿ãµããŒããããŠããã32Gb FCã«ãŒãã¯çŸåšã®äžä»£ã®FAS / AFFã§äœ¿çšã§ããŸãã
10GbE Base-TããŒãã¯FAS2520ã³ã³ãããŒã©ãŒããFAS8200ã«ç§»åããŸãã:)ãããã¯ã¯ã©ã¹ã¿ãŒçžäºæ¥ç¶ããã³ã¯ã©ã€ã¢ã³ãæ¥ç¶ã«äœ¿çšã§ããŸãã ãŸãã1GbEã®é床ã§äœæ¥ããµããŒãããŸãã
FAS9000
ããã§ã¯ãFAS8060ãšFAS8080 EXã眮ãæããããã«æ¥ãã¢ã³ã¹ã¿ãŒã«ã€ããŠè©±ããŸãããã
çŸåšã®äžä»£ã§ã¯ãFAS80x0ã©ã€ã³å šäœã1ã€ã®ã·ã£ãŒã·ã¢ãŒããã¯ãã£ãå ±æããŠããŸãã FAS9000ã¯ãã¡ã³ããã³ã¹ãšæ¡åŒµãç°¡çŽ åããæ°ããã¢ãããŒããæ¡çšããŠããŸãã
ããããæè¡ä»æ§ãšFAS8080 EXãšã®æ¯èŒããå§ããŸãããã
FAS8080 EXã«æ¯ã¹ãŠããã©ãŒãã³ã¹ã50ïŒ
åäžããŸããïŒ
- 72ã³ã¢-18ã³ã¢ã®4ããã»ããµãŒ
- 1024GB DDR4ã¡ã¢ãª-4å
- 2åã®æ°ã®NVRAM
- 2TiB NVMe FlashCacheã16TiBã«æ¡åŒµå¯èœ
- 80Gb /ç§åž¯åå¹ ã®NVRAMãã©ãŒãªã³ã°
ããŠãä»æãèå³æ·±ãã®ã¯èé¢å³ã§ãã
æ°ããã¢ãžã¥ãŒã«èšèšã ã³ã³ãããŒã©ã«ã¯ã¯ã©ã€ã¢ã³ãããŒãããããŸããã ã³ã³ãããŒã©ãŒãšæ¡åŒµã¢ãžã¥ãŒã«ã¯ãããã¹ã¯ããããµããŒãããŠããŸãã çŸåšãæ¡åŒµã¢ãžã¥ãŒã«ã¯ã³ã³ãããŒã©ãŒãšã¯å¥ã«ãã©ã€ããã§ããããããããã亀æããå Žåããã§ã€ã«ãªãŒããŒãå®è¡ããå¿ èŠã¯ãªããä»ã®ã¢ãžã¥ãŒã«ããã®ã±ãŒãã«ã«åé¡ã¯ãããŸããã ãããŠãæãèå³æ·±ãã®ã¯ããã®ã·ã£ãŒã·ã«ãããå°æ¥FAS9000ã³ã³ãããŒã©ãŒãæ°ãããã®ã«äº€æã§ããããšã§ãã
ã¹ãããã®æ°ãå°ãªããã³ã³ãããŒã©ãŒèªäœã«ããŒãããªãã«ãããããããã¯ã©ã€ã¢ã³ããæ¥ç¶ããéã®ã¹ã±ãŒã©ããªãã£ã¯äœäžããŸããã FlashCacheã¯åå¥ã®ã¹ãããã䜿çšããŸãã ãµããŒããããããŒãã¯40GbEããã³32Gb FCã§ãã ã¡ãªã¿ã«ã40GbEããŒãã¯ã¯ã©ã¹ã¿ãŒçžäºæ¥ç¶ã«äœ¿çšãããããã«ãªããŸããã
AFF A300ããã³AFF A700
FASãç解ãããªãŒã«ãã©ãã·ã¥ã·ã¹ãã ã«ç§»è¡ããŸãã ãªãŒã«ãã©ãã·ã¥ã¢ãã«ã¯2ã€ã«ãªããåœåæ¹æ³ããããã«å€æŽãããŸããã
ãã¡ãããæãç¬åµçãªäººã¯ãAFFã·ã¹ãã ã«ã¯FAS8200ããã³FAS9000ãšåãé補ãã©ãããã©ãŒã ã䜿çšãããŠããããšã«æ°ä»ããŸããã ãããã£ãŠãæè¡ä»æ§ã詳现ã«èª¬æããããšã¯ããããããã®äžéšã«ã€ããŠã®ã¿èª¬æããŸãã
- A300ã¯ãAFF8040ããã1msã®ã¬ã€ãã³ã·ã§50ïŒ é«ãããã©ãŒãã³ã¹ãå®çŸããŸã
- æ倧384 SSDããµããŒã
å©çšå¯èœãªSSD 15.3TBã3.8TBã960GB
- A700ã¯ãAFF8080ã®ååã®ã¬ã€ãã³ã·ã§2åã®ããã©ãŒãã³ã¹ãå®çŸããŸã
- æ倧480 SSDããµããŒã
- å©çšå¯èœãªSSD 15.3TBã3.8TBã960GB
ãããŠãã¡ãããã©ã¡ãã®ã¢ãã«ã40GbEã32Gb FCã€ã³ã¿ãŒãã§ã€ã¹ããµããŒãããŠããŸãã 次ã«ãããã©ãŒãã³ã¹ã«ã€ããŠå°ã説æããŸãããã
ãã®ãããªé²æ©ã¯ãéã®ãã©ãããã©ãŒã ãæŽæ°ããã ãã§ã¯éæã§ããŸããã ONTAP 9.1ã«ãããNetAppã¯SSDåãã®ãã«ãã¹ããªãŒã æžã蟌ã¿ãã¯ãããžãŒã®ãµããŒããéå§ããæåã®äŒæ¥ãšãªããŸããã åœåããã®æè¡ã¯ãµã ã¹ã³ã§éçºãããŸããã 2015幎æ«ã«ããã®ãã¯ãããžãŒã¯T10 SCSIèŠæ Œã®äžéšã«ãªããŸããã NVMeæšæºã«ãå«ãŸããŸãã
ãã«ãã¹ããªãŒã SSD
ãã®æè¡ã¯äœã§ããïŒ ãŸããããã€ãã®ããç¥ãããæ å ±ã SSDãžã®æžã蟌ã¿ã¯ãHDDãžã®æžã蟌ã¿ãšã¯éåžžã«ç°ãªãããšã誰ããç¥ã£ãŠããŸãã SSDã«ã¯æ¬è³ªçã«æžãæããªã©ã®æäœã¯ãããŸããã äžéšã®ããŒã¿ãå€æŽããå Žåã¯ãå€ãããŒã¿ãæ¶å»ããŠãå€æŽããããŒã¿ãæžãæããå¿ èŠããããŸãã åé¡ã¯ã空ã®å Žæãžã®èªã¿åããšæžã蟌ã¿ãããŒãžã®ç²åºŠã§çºçããããšã§ãããåé€ããå Žåã¯ãè€æ°ã®ããŒãžã§æ§æããããããã¯ãæ¶å»ããå¿ èŠããããŸãã ãããã¯ããç¥ãããŠããP / Eã«ãŒãïŒããã°ã©ã /æ¶å»ïŒã§ãã ããã¯ãã¹ãŠãSSDã®å¯¿åœã®äœäžãšããã£ã¹ã¯ããã£ã±ãã®ãšãã®æžã蟌ã¿ããã©ãŒãã³ã¹ã®äœäžã«ã€ãªãããŸãã
NANDã»ã«ã¯äžå®æ°ã®P / Eãµã€ã¯ã«çšã«èšèšãããŠãããããèçšå¹Žæ°ãççž®ãããŸãã ããã©ãŒãã³ã¹ã®èŠ³ç¹ãããSSDã³ã³ãããŒã©ãŒã¯ç©ºçœããŒãžã«ããŒã¿å€æŽãæžã蟌ãããšããŸãã å®æçã«ãå€ãããŒã¿ã§ãããã¯ãã¯ãªãŒã³ã¢ããããããã«ãã¬ããŒãžã³ã¬ã¯ã¿ãŒãèµ·åããããããã¯ã解æŸãããŸãã æ°ããããŒã¿ãšå€æŽãããããŒã¿ãèšé²ããããã®ç©ºãããŒãžãããéããGCã¯ããã¯ã°ã©ãŠã³ãã§åäœããããã©ãŒãã³ã¹ã«ç¹ã«åœ±é¿ããŸããã ãã ããããçšåºŠã®ãã£ã¹ã¯ããã£ã±ãã«ãªããšãGCãããç©æ¥µçã«æ©èœãå§ããèšé²çšã®SSDã®ããã©ãŒãã³ã¹ãå€§å¹ ã«äœäžããŸãã SSDã¯ããã¹ãããæ¥ããããå€ãã®æäœãå®è¡ããå¿ èŠããããŸãã ããã¯Write AmplificationãšåŒã°ããŸãã å žåçãªæžã蟌ã¿ã®åŽã¯ãSSDããã©ãŒãã³ã¹ã°ã©ãã«è¡šç€ºãããŸãã
ãµã ã¹ã³ã¯ããã¹ãããéä¿¡ãããããŒã¿ãåé¡ããããšã«ããŸããã ããŒã¿ã¯ç¹å®ã®ã¹ããªãŒã ã«é¢é£ä»ããããŠããŸãã 1ã€ã®ã¹ããªãŒã ã«ã¯ãåæã«å€æŽãŸãã¯åé€ãããå¯èœæ§ãé«ãããŒã¿ãå«ãŸããŠããŸãã ç°ãªãã¹ããªãŒã ããã®ããŒã¿ã¯ãSSDã®ç°ãªããããã¯ã«æžã蟌ãŸããŸãã
ãã®ã¢ãããŒãã«ãããSSDã®èä¹ æ§ãåäžãããããã©ãŒãã³ã¹ãåäžãããå®å®ããã¬ã€ãã³ã·ãæäŸã§ããŸãã ãµã ã¹ã³ã®å éšãã¹ãã«ãããšããã«ãã¹ããªãŒã æžã蟌ã¿ãã¯ãããžãŒã«ããæžã蟌ã¿å¢å¹ ãååã«ãªããèä¹ æ§ãæ倧3åã«ãªããã»ãšãã©ã®å Žåé 延ã50ïŒ æžå°ããŸãã
ããããã¹ãŠã¯ãONTAP 9.1ãæèŒããNetApp AFFã·ã¹ãã ã§å©çšå¯èœã«ãªããŸããã
ãã«ãã¹ããªãŒã SSDã®è©³çŽ°ã«ã€ããŠã¯ã次ã®ãã¬ãŒã³ããŒã·ã§ã³ãšã¬ããŒããã芧ãã ããã
ããã«ãã¹ããªãŒã ãœãªããã¹ããŒããã©ã€ããã®ãã¬ãŒã³ããŒã·ã§ã³- ã«ã³ã»ãžã§ã³ãŠã¯ããžã§ãœã¯ã»ãã§ã³ããã§ã³ãžã¥ã»ã¡ã³ããã§ã€ã»ãµã³ãŠã³
ãã¬ãŒã³ããŒã·ã§ã³ããã«ãã¹ããªãŒã æžã蟌ã¿SSDã§ãã«ãã¹ããªãŒã æžã蟌ã¿SSDã®ããã©ãŒãã³ã¹ãšå¯¿åœãåäžãããã- ãã£ã³ããã§ã€å士
ONTAP 9.1
ONTAPã®æ¬¡ã®ããŒãžã§ã³ã§ã¯ãä»ã«äœãæ°ãããªããŸãããïŒ FlexGroupsãµããŒãã ãããã¯ãæ倧20PBããã³4,000ååã®ãã¡ã€ã«ãä¿åã§ããã¹ã±ãŒã©ãã«ãªãã¡ã€ã«ã³ã³ãããŒã§ãã 1ã€ã®FlexGroupã¯ã¯ã©ã¹ã¿ãŒå ã®è€æ°ã®ã³ã³ãããŒã©ãŒã«é 眮ã§ããŸãããã¯ã©ã¹ã¿ãŒã¯ãã¡ã€ã«ã®æžã蟌ã¿æã«èªåçã«è² è·ãåæ£ããŸãã NFSãšSMBããµããŒããããŠããŸãã FlexGroupsã®è©³çŽ°ãã芧ãã ããã
ç¹å¥ãªèªå·±æå·åãã£ã¹ã¯ããã³å€éšããŒãããŒãžã£ãŒã䜿çšããªãããŒã¿æå·åã®ãµããŒãã NetAppããªã¥ãŒã æå·åïŒNVEïŒã æå·åã¯ããªã¥ãŒã ã¬ãã«ã§è¡ãããŸãã ã€ãŸããæå·åããããªã¥ãŒã ãšæå·åããªãããªã¥ãŒã ãéžæã§ããŸãã ããªã¥ãŒã ããšã«åå¥ã®æå·åããŒã䜿çšãããŸãã æå·åã¯ONTAPã«çµã¿èŸŒãŸãããœãããŠã§ã¢ã¢ãžã¥ãŒã«ã§è¡ãããããŒããŠã§ã¢ã¢ã¯ã»ã©ã¬ãŒã·ã§ã³ã¯Intelããã»ããµã®ã¬ãã«ã§äœ¿çšãããŸãã åæã«ããã¹ãŠã®NetAppããã©ãŒãã³ã¹ãã¯ãããžãŒã®å©ç¹ã¯æ®ããŸãã WAFLã¯ãããŒã¿ãæå·åãããåã«åŠçããŸãã
MetroClusterã§ãµããŒããããŠããäœæ¥ã æå·åãããŠããªãããªã¥ãŒã ãããæå·åãããããªã¥ãŒã å ã®å¥ã®ã·ã¹ãã ã«ããŒã¿ãè€è£œããããšãã§ããŸãã ONTAP Selectã§ãµããŒããããŠããŸãã ãããŠãåå·ç è ã¯ãNVEãšNSEãã©ã€ãã¬ãã«æå·åãšãã2ã€ã®æå·åæ¹æ³ã䜿çšã§ããŸãã æ®å¿µãªããããããã¯ãã¹ãŠãã·ã¢ã§ã¯å©çšã§ããŸããã NVEãµããŒãã®æç¡ã«ãããããã2ã€ã®ç°ãªãONTAPã€ã¡ãŒãžã䜿çšãããŸãã
ONTAP Selectã¯ããªãŒã«ãã©ãã·ã¥æ§æããµããŒãããããã«ãªããŸããã ãŸããONTAP Cloudã¯MS Azureã§å ¬åŒã«åçãäžããŸããã
ããŠããããŠæãéèŠãªã®ã¯ãSANãããã³ã«ã䜿çšããã¯ã©ã¹ã¿ãŒã®å Žåãã¯ã©ã¹ã¿ãŒå ã®ã³ã³ãããŒã©ãŒæ°ã®å¶éãå¢å ããããšã§ãã çŸåšããã®ãããªã¯ã©ã¹ã¿ãŒã¯12ããŒããŸãã¯6çµã®ã³ã³ãããŒã©ãŒã§æ§æã§ããŸãã ãã®ããããã¡ã€ã«ãããã³ã«ã®ã¿ã䜿çšããå Žåãç§ãæžããã³ã³ãããŒã©ãŒã®ãã¹ãŠã®æè¡ä»æ§ãšå¶éã«6ãŸãã¯12ãæããããšãã§ããŸãã
ã¡ãªã¿ã«ãNetAppãœãªã¥ãŒã·ã§ã³ã«èå³ããã人ã®ããã«ãããŒãå¥ã®é»å ±ãã£ãã«ããããŸãã