VMwareã¯ãvSphereãã©ãããã©ãŒã åãã®æ¬¡äžä»£ãšã³ã¿ãŒãã©ã€ãºã¬ãã«ã®çµã¿èŸŒã¿ã¹ãã¬ãŒãžã§ããVMware vSAN 6.6ã®ãªãªãŒã¹ã4æ14æ¥ã«å°å
¥ããŸãããããã¯ã2013幎10æã®æåã®ããŒãžã§ã³ã®ãªãªãŒã¹ä»¥éã絶ããæ¹åãããŠããŸããå€ãã®å€æŽããããäŒæ¥ãŠãŒã¶ãŒã«æè¿ãããŸãã
VMwareã«ãããšããã®Virtual SANïŒvSANïŒ*ã¯ãHyper-Converged InfrastructureïŒHCIïŒãœãããŠã§ã¢ã«ãšã£ãŠæ¥çã§å§åçã«æé«ã§ãã
* VMware Virtual SANâãµãŒããŒãã£ã¹ã¯ãšãã©ãã·ã¥ãã©ã€ãããé«ãããã©ãŒãã³ã¹ãšãã©ãŒã«ããã¬ã©ã³ã¹ãåããä»®æ³ãã·ã³çšã®å
±éã®åæ£ããŒã¿ã¹ãã¬ãŒãžã«çµåããçŽæ¥æ¥ç¶åã¹ãã¬ãŒãžä»®æ³åãã¯ãããžã
補åã®ææ°ããŒãžã§ã³ã¯ãçµã¿èŸŒã¿ã®ããã€ãã£ãã HCIã»ãã¥ãªãã£ããŒã«ããæ¡åŒµãé«å¯çšæ§ã¯ã©ã¹ã¿ãŒã次äžä»£ããžãã¹ã·ã¹ãã ã®é«ã¯ãŒã¯ããŒãåãã®çç£æ§ã50ïŒ
åäžããå®å
šãã©ãã·ã¥ã·ã¹ãã ã§ããã®äººæ°ã®ãããœãªã¥ãŒã·ã§ã³ãè£å®ããŸãã
äžè¬çãªè£œåã®èª¬æ
ä»æ¥ãããããæ¥çããã³ããããèŠæš¡ã®7,000瀟ãè¶
ããã客æ§ãvSANã®æ©èœã䜿çšããŠãITã€ã³ãã©ã¹ãã©ã¯ãã£ãç°¡çŽ åããéèŠãªããžãã¹ã¢ããªã±ãŒã·ã§ã³ããä»®æ³ãã¹ã¯ããããŸã§ããšã³ã¿ãŒãã©ã€ãºã¯ãŒã¯ããŒãã管çããŠããŸãã å
žåçãªvSANæ©èœã¯æ¬¡ã®ãšããã§ãã
ãªã¹ã¯ã®ãªãå±é
ã¯ã©ãŠãã€ã³ãã©ã¹ãã©ã¯ãã£ãäœæããããã®ãµãŒããŒä»®æ³åãã©ãããã©ãŒã ã§ããvSphereã®å¯äžã®ããã€ãã£ããããŒã¿ãŠã§ã¢ããŠã¹ãšããŠãvSANã䜿çšãããšãä»®æ³åãã¹ãã¬ãŒãžã·ã¹ãã ã«æ¡åŒµããæ¢åã®ããŒã«ãå€æ°ã®ãœãããŠã§ã¢è£œåãããŒããŠã§ã¢ãã©ãããã©ãŒã ã ãã§ãªãããã§ã«å©çšå¯èœãªãã€ããŒã³ã³ããŒãžããœãªã¥ãŒã·ã§ã³ãäœæã§ããŸãå°é家ãšãŠãŒã¶ãŒã®ã¹ãã«ã
VMware vSphereã®åºæ¬æ
å ±ã¯ãã¡ãããå
¥æã§ããŸã ã
ææ°ããŒãžã§ã³ã§ã¯ãvSANã¯æ¥çåã®çµ±åHCIã»ãã¥ãªãã£ãœãªã¥ãŒã·ã§ã³ã«ããããšã³ã¿ãŒãã©ã€ãºãªã¹ã¯ãããã«äœæžããŸãã ã·ã¹ãã ã¯ãããŒã¿ãä¿è·ããªãããç°¡åãªã¹ãã¬ãŒãžç®¡çãæäŸããŸãã
倧æãµãŒããŒãããã€ããŒã®å€§èŠæš¡ã§å®çžŸã®ããvSAN ReadyNodeãšã³ã·ã¹ãã ã«ãã£ãŠæäŸããããvSANã«ã¯å¹
åºãå±éãªãã·ã§ã³ããããŸãã
TCOåæž
ITäºç®ãéãããŠããã¯ã©ã€ã¢ã³ãã¯ãç·ææã³ã¹ãïŒç·ææã³ã¹ããTCOïŒã50ïŒ
ã«åæžãããããvSANã«åºã¥ãHCSã·ã¹ãã ã䜿çšããããšããããããŸãã VSANã·ã¹ãã ã¯ãé©åãªããŒããŠã§ã¢ãéžæãããã©ãã·ã¥ãã¯ãããžãŒã䜿çšããããšã§ãã€ãŸããµãŒããŒåŽã·ã¹ãã ã®æé«ã®çµæžçããã©ãŒãã³ã¹ã«ãããåçã«ã³ã¹ããåæžã§ããŸãã
äžè¬ã«ãã¹ãã¬ãŒãžã¡ã³ããã³ã¹ã¢ã¯ãã£ããã£ã¯ãããå°ãªãã¿ã¹ã¯ã§ç°¡åã«ãªã£ãŠããŸãã ã€ã³ããªãžã§ã³ããªãŒãã¡ãŒã·ã§ã³ã¯1ã€ã®ããŒã«ã§å¶åŸ¡ã§ããè¿œå ã®å°é家ãåŒãä»ããå¿
èŠã¯ãããŸããã
ã¹ã±ãŒãªã³ã°
äŒæ¥ãæé·ããã«ã€ããŠãvSANã®ãä¿ææ§ãã¯ãææ¥ã®ITãžã®æºåãã€ãŸããããªãã¯ã¯ã©ãŠããžã®æ¡åŒµããŸãã¯æ°ãããã¯ãããžãŒã®è¿
éãªå±éãæ¯æŽãã競äºåãé«ããŸãã
vSANã¯ãã¬ã¬ã·ãŒã¯ãªãã£ã«ã«ã·ã¹ãã ããã³ã³ããã¢ãŒããã¯ãã£ãŸã§ãå¹
åºãã¢ããªã±ãŒã·ã§ã³ããµããŒãããŠããŸãã VMware NSXãã©ãããã©ãŒã ãšçµã¿åãããããšã§ãvSANã¯SDDCïŒSoftware-Defined Data CenterïŒã¹ã¿ãã¯ã倧å¹
ã«åŒ·åãããªã³ãã¬ãã¹ã®ã¹ãã¬ãŒãžã·ã¹ãã ãšç®¡çãµãŒãã¹ããããªãã¯ã¯ã©ãŠãã«æ¡åŒµã§ããŸãã vSAN 6.6ã®äž»ãªæ°æ©èœãšæŽæ°ã«ã¯ã次ã®ãã®ãå«ãŸããŸãã
æ¥çåã®HCIãã€ãã£ãæå·å
vSANã¯ãä¿åãããïŒæªäœ¿çšã®ïŒããŒã¿ã«å¯ŸããŠHCIæå·åãœãªã¥ãŒã·ã§ã³ãæäŸããäžèŠãªã¢ã¯ã»ã¹ããããŒã¿ãä¿è·ããŸãã VSANæå·åã¯ãåæ§ã®ã·ã¹ãã ãããå®äŸ¡ã§æè»æ§ããããŸãã ããŸããŸãªã¡ãŒã«ãŒã®ããŸããŸãªããŒããŠã§ã¢ã§äœ¿çšã§ããŸãã ãœãããŠã§ã¢ã¯ãç°¡çŽ åãããããŒç®¡çãå®è£
ããŸãã
ãã®çµæãèªå·±æå·åãã©ã€ãïŒ SED ïŒã¯äžèŠã«ãªããŸããã VSANæå·åã¯ã2èŠçŽ èªèšŒïŒSecurIDããã³CACïŒã®èŠä»¶ã«åŸã£ãŠå®è£
ãããŠãããé²è¡æ
å ±ã·ã¹ãã å±ã«ãã£ãŠèªå®ãããã»ãã¥ãªãã£æè¡å®è£
ã¬ã€ãïŒSTIGïŒãæã€æåã®HCIãœãªã¥ãŒã·ã§ã³ã§ãã ã DISA ïŒã
ããŒã«ã«ãµã€ãä¿è·ãåããæ¡åŒµã¯ã©ã¹ã¿ãŒ
ããŒã«ã«ãµã€ãä¿è·ãåããæ°ããæ¡åŒµãã¹ãã¬ãããã¯ã©ã¹ã¿ãŒã¯ãå€éšãããã¯ãŒã¯ã·ã¹ãã ïŒãµã€ã*ïŒããã³ãªã³ãã¬ãã¹ã·ã¹ãã ã®ä¿è·ãšãã©ãŒã«ããã¬ã©ã³ã¹ãæäŸããŸããããã®ãããªæ©èœã®ã³ã¹ãã¯åŸæ¥ã®ãœãªã¥ãŒã·ã§ã³ã«æ¯ã¹ãŠäœãïŒæ倧50ïŒ
ïŒã§ãã
*ãã®æèã§ã¯ãã ãµã€ã ãïŒãµã€ãïŒã®æŠå¿µã¯ããåºãç解ãããŠããŸããã€ãŸããåãªããŠã§ãããŒãžã®ããŒãã»ããã§ã¯ãªããçµ±åã€ã³ãã©ã¹ãã©ã¯ãã£ã®ãµã€ããšããŠã§ãã
å®å
šãªæ¡åŒµã¯ã©ã¹ã¿ãŒãœãªã¥ãŒã·ã§ã³ã¯ãã·ã³ãã«ã§äœã³ã¹ãã®çœå®³åŸ©æ§ãæäŸããããžãã¹ç¶ç¶æ§ã®èŠä»¶ãæºãããŸãã
ããã«ãvSANã¯ã©ãŠãåæããŒã«ã¯ãvSANãã«ã¹ãµãŒãã¹ã䜿çšããŠãã·ã¹ãã ã®ã¹ããŒã¿ã¹ããã³é¢é£ããæšå¥šäºé
ã«é¢ãããªã¢ã«ã¿ã€ã ã®ããã¢ã¯ãã£ããªéç¥ãèªåçã«è¡šç€ºããããšã«ãããéçšã³ã¹ããåæžããŸãã
vSANã¯ã以å䜿çšãããŠãããã«ããã£ã¹ãã®ä»£ããã«ãvSANã®åæã€ã³ã¹ããŒã«ãç°¡çŽ åãããŠããã£ã¹ããããã¯ãŒã¯ãã¯ãããžãŒããµããŒãããããã«ãªããŸããã
ããã«ããããããã¯ãŒã¯ãå€æŽããããšãªããåºç¯å²ã®ãªã³ãã¬ãã¹ããã³ã¯ã©ãŠãå±éãªãã·ã§ã³ã§vSANã䜿çšã§ããŸãã
æ°ãããvSAN Management Pack for VMware vRealize Operations Managerãã¯ãvSANã®èª€åäœãç£èŠã管çãããã³æ€åºããããã®è¿œå ãªãã·ã§ã³ãšãå®å
šãªã€ã³ãã©ã¹ãã©ã¯ãã£ãœãªã¥ãŒã·ã§ã³ãæäŸããŸãã
åžžæä¿è·
Always-On Protectionã°ã«ãŒãã®æ°æ©èœã«ãããvSANã¯æœåšçãªããŒããŠã§ã¢ã®åé¡ã«ãããããããã¢ããªã±ãŒã·ã§ã³ã®æäœãšå¯çšæ§ããµããŒãã§ããŸãã
ã³ã³ããŒãã³ããDegraded Device HandlingãïŒDDHïŒã¯ããã£ã¹ã¯ã®åäœãå®å
šã«å¶åŸ¡ããé害ã®å¯èœæ§ãããå ŽåãéèŠãªããŒã¿ãå¥ã®å Žæã«äºåã«ç§»åããŸãã ãã®åŸãå¿
èŠã«å¿ããŠããã£ã¹ã¯ãšãã®ããŒãã£ã·ã§ã³ã®åæ§æãšãªã«ããªãå®è¡ãããŸãã
ã©ã€ããµã€ã¯ã«ç®¡ç
Intelligent Operations and Lifecycle Managementã°ã«ãŒãã®æ°ããããŒã«ã¯ãããŒããŠã§ã¢ãšãœãããŠã§ã¢ã®åæã€ã³ã¹ããŒã«ãå éããŸãã ãŸããããŒããŠã§ã¢ã®ã©ã€ããµã€ã¯ã«ãç°¡åã«ç®¡çããå°æ¥ã®åäœãäºæž¬ããŸãã
ãã¯ã³ã¯ãªãã¯èªååãã«ãããäžè¬çãªã¿ã¹ã¯ã®ç®¡çæéã¯80ïŒ
ã«ççž®ãããŸãã æé©åãããããŒã¿ãµãŒãã¹ã¯ã以åã®vSANããŒãžã§ã³ããããã©ãã·ã¥ãã©ã€ãã䜿çšããããã€ã¹ã«æ倧50ïŒ
ã®I / Oæäœ/ç§ïŒIOPSïŒãæäŸããããšã«ãããvSANã®ããã©ãŒãã³ã¹ãããã«åäžãããŸãã
æ°ããã¢ãŒããã¯ãã£ã«ãããSplunkãBig DataãCitrix XenAppãªã©ã®æ¬¡äžä»£ã¢ããªã±ãŒã·ã§ã³ã®å±éãå¯èœã«ãªããŸãã ããã«ãPhotonã®vSANãPhoton Platform 1.1ããã³æ°ããDockerããªã¥ãŒã ãã©ã€ããŒã§å©çšã§ããããã«ãªããŸããã
ã客æ§ã¯ãæ°ããIntel Optane 3D XPoint NVMe SSDãã©ãã·ã¥ãã©ã€ãã®ãDay 1 Supportãã¢ãããŒãã®äžéšãšããŠããŒããŠã§ã¢ã®å°å
¥ãå éã§ããŸãã ããã«ãvSANã«ã¯ã1.6 TBãã©ãã·ã¥ãã©ã€ããªã©ããã£ãã·ã¥ã®éãå¢ããããã®ãªãã·ã§ã³ãçšæãããŠããŸãã
VMware Ready for vSAN Programã䜿çšãããšããµãŒãããŒãã£ããŒãããŒã®ããŒã¿ä¿è·ããã³ãã¡ã€ã«ãµãŒãã¹ã䜿çšããŠvSANç°å¢ãæ¡åŒµããã³æ¡åŒµã§ããŸãã
詳现-vSAN 6.6ã®æ°æ©èœ
vSAN 6.6ãšããã©ãã«ãä»ããæ°ããVMware vSANãªãªãŒã¹ã¯ãvSphereãªãªãŒã¹ã®ã·ãªã¢ã«çªå·ãšäžèŽããŸããã ããããvSphereã®å€§ããªããããšèŠãªãããšãã§ããŸããåæã«ãä»æ¥ã®vSANã®ã¡ã€ã³ãªãªãŒã¹ã§ããããŸãã 以åã¯ãStretched ClusteringãåãããªãªãŒã¹6.2ãšãiSCSIããã³2ããŒããã€ã¬ã¯ãã³ãã¯ããåãããªãªãŒã¹6.5ãçºè¡šãããŸããã
ãã ããvSAN 6.6ã«ã¯ãæ°ãã䟿å©ãªæ©èœãšããŸããŸãªæ¹åç¹ãå€æ°ãããŸãã æ¹åç¹ã®äžè¬çãªãªã¹ãã¯æ¬¡ã®ãšããã§ãã
-vSANæå·åâå¹æçãªå§çž®ã«ããããŒã¿ã¹ãã¢ã¬ãã«ã®æå·åã
-ã¹ãã¬ããã¯ã©ã¹ã¿ã®ããŒã«ã«ä¿è·ããŒã«ã
-ãã«ããã£ã¹ãã®åäœåçãåé€ã
-ESXi Host ClientïŒHTML-5ïŒã®ç®¡çããã³ç£èŠæ©èœã
-é«åºŠãªãªãã©ã³ã¹ã
-é«åºŠãªå埩;
-é«åºŠãªåæãšååæã
-ãµãŒãã¹ã®äºåãã§ãã¯ã
-ã¹ãã¬ããã¯ã©ã¹ã¿çšã®é«åºŠãªãŠãŒã¶ãŒã€ã³ã¿ãŒãã§ã€ã¹ã
-vSANã¯ãã¯ã©ãŠãããŒã¹ã®ãã«ã¹ãã§ãã¯ãå«ãPhone Home /ã«ã¹ã¿ããŒãšã¯ã¹ããªãšã³ã¹åäžããã°ã©ã ã«å«ãŸããŠããŸãã
-é«åºŠãªAPI;
-vSANã®ã€ã³ã¹ããŒã«ã容æã«ããæ段ã
-vSAN Config Assist /ãã¡ãŒã ãŠã§ã¢ãæŽæ°ã
-ããã©ãŒãã³ã¹ãšãã«ã¹ã®ç£èŠã®åŒ·åã
ããªã倧ããªãªã¹ãã 説æãå¿
èŠãªç¹ãããã€ããããŸãããããã¯ä»¥äžã«æŠèª¬ãããŠããŸããâããã€ãã¯ãããèªäœã§èªã£ãŠããŸããããšãã°ããã«ããã£ã¹ã/ãŠããã£ã¹ãã®å Žåã®ããã«ã
vSANæå·å
ææ°ãªãªãŒã¹ã§ç¹ã«æ³šç®ãã¹ãæ¹åç¹ã¯ãvSANæå·åã§ãã ãåç¥ã®ããã«ãvSphere 6.5ã¯VAIOïŒIO Filtersçšã®vSphere APIïŒã«åºã¥ããVMIOæå·åãå°å
¥ããŸããã
ãã ããå®å
šãªvSANãã©ãã·ã¥ã䜿çšããã¯ã©ã€ã¢ã³ãã«ã¯ãæå·åãæé«ã¬ãã«ã§å®è¡ããããã€ãŸãIOãæå·åããããšãã倧ããªäžäŸ¿ãã1ã€ãããŸããã ãã®çµæãå§çž®ã®å©ç¹ã¯ãŒãã«è¿ãããšãå€æããŸããã ãããã£ãŠãvSANæå·åãå°å
¥ãããŸããã
èªå·±æå·åãã©ã€ãã¯å¿
èŠãããŸããã ããã¯ã䜿çšããã¹ãã¬ãŒãžããã€ã¹ã®ç¹å®ã®ã¿ã€ãã«é¢ä¿ãªãããã€ããªããã·ã¹ãã ãŸãã¯ãã«ãã©ãã·ã¥ã·ã¹ãã ã§åäœããæä»çãªãœãããŠã§ã¢ãœãªã¥ãŒã·ã§ã³ã§ãã
vSANã§æå·åãæ§æãã
ã¹ãã¬ããã¯ã©ã¹ã¿ã®ããŒã«ã«ä¿è·
ãã¹ãã¬ããã¯ã©ã¹ã¿ã®ããŒã«ã«ä¿è·ãâéåžžã«éèŠã§äŸ¿å©ãªæ©èœãâããããã¹ãã¬ããã¯ã©ã¹ã¿ãå®è£
ãããŠä»¥æ¥ãæãéèŠãªæ©èœã§ãã 以åã®ãªãªãŒã¹ã§ã¯ããµã€ãã«RAID1æ§æãäœæã§ããŸãããã€ãŸããåãµã€ãã«1ã€ãã€ãããŒã¿ã®ã³ããŒã2ã€ã ãäœæããŸããã
ãã ããã³ããŒã®1ã€ã«ãšã©ãŒãçºçããå Žåãåšåº«ã«æ®ã£ãŠããã®ã¯1ã€ã®ã³ããŒã®ã¿ã§ãããå¥ã®é害ã«ããããŒã¿ã倱ãããå¯èœæ§ãããããšãæå³ããŸãã ããã¯ãããããã®ãµã€ãã§é害ãçºçããå Žåãååæãå¿
èŠã§ããããšãæå³ããŸãã
VSAN 6.6ã¯ããã®æœåšçãªè
åšãæé€ããŸãã ããã§ãããã©ã€ããªFTTããšãã»ã«ã³ããªFTTããã€ãŸã蚱容ãããé害ã®æ°ïŒèš±å®¹ãããé害ã®æ°ãFTTïŒãèšå®ã§ããŸãã ãã®ã€ã³ãžã±ãŒã¿ã¯ãvSANå
ã®ãªããžã§ã¯ãã®ã匟åæ§ãããšã©ãŒæ°ããããã決å®ããŸãã
vSAN 6.6ã®FTTãã¯ãããžãŒã¯ãä¿è·ã®ããã®ãµã€ãéžæãšããŒã«ã«ä¿è·ã®ã¬ãã«ãæäŸããŸã
ãã©ã€ããªFTTã®å€ã¯ãã¹ãã¬ããã¯ã©ã¹ã¿ã§0ãŸãã¯1ã«èšå®ã§ããŸãã1ã¯ãã¯ã©ã¹ã¿ãã¹ãã¬ãããããããšãæå³ããŸãã 次ã«ãã»ã«ã³ããªFTTã§ããµã€ãã§ã·ã¹ãã ãä¿è·ããæ¹æ³ã決å®ã§ããŸãã ããšãã°ãè€æ°ã®ããŒã«ã«ã³ããŒãæã€RAID1ããŸãã¯RAID5ãšRAID6ã§ãããŸããŸããã
ãŠã£ãããã¹VM
vSANã¹ãã¬ããã¯ã©ã¹ã¿ãŒæ§é ã®VMã®ç£èŠ
ã¹ãã¬ããã¯ã©ã¹ã¿ãŒãå®è£
ãããŠããå Žåã¯ãæ°åã¯ãªãã¯ããã ãã§ããŠãŒã¶ãŒã€ã³ã¿ãŒãã§ã€ã¹ããçŽæ¥ããç®æè
ãã§ããWitness VMãç°¡åã«çœ®ãæããããšãã§ããŸãã
Witness VMãã¹ãã®äº€æã¯ãããŸã§ã«ãªãç°¡åã«ãªããŸãã
ESXiãã¹ãã¯ã©ã€ã¢ã³ã
圹ç«ã€ã®ã¯ãESXi Host Clientã§ã®ãvSANã¯ãŒã¯ãããŒãã®æŠå¿µã®å°å
¥ã§ãã äœããã®çç±ã§vCenter Serverã«ã¢ã¯ã»ã¹ã§ããªãå ŽåãESXiãã¹ãã«ã¢ã¯ã»ã¹ããŠãå¶åŸ¡ããã³ç£èŠæ©èœãä¿æã§ããŸãã
ESXiã§ã®vSANèšå®ã®æ§æ
ãã¹ãã¯ã©ã€ã¢ã³ãã®ãã«ã¹ãã§ãã¯çšã®ããã«ã¹ã¹ããŒã¿ã¹ãããã·ã¥ããŒãããããŸãã
vSAN 6.6ã®ãã®ä»ã®æ©èœ
å€ãã®ã客æ§ã¯ãå¶æ¥æéäžã®ååæäžã«æ¶è²»ããã垯åå¹
ãçããããšèšã£ãŠããŸãã ããã¯ããŠãŒã¶ãŒã€ã³ã¿ãŒãã§ã€ã¹ããçŽæ¥äœ¿çšã§ãããªãã·ã§ã³ã§ãã ãã ãããã®ããã©ã«ãå€ãèšå®ããããšã¯ãå§ãããŸãããååæãæå¶ããããšã¯ããã®å®è£
ã®æéãå¢ããããšãæå³ããããã§ãã
ããšãã°ãã¿ã¹ã¯ãå®äºããããšãã§ããªãå Žåããç¹å®ã®åé¡ãããå Žåã«ãé©åãªã¡ãã»ãŒãžãçºè¡ããã¡ã³ããã³ã¹ãã§ãã¯ããŒã«ãé«ãè©äŸ¡ããŸãã
ãã£ã¹ã¯ã°ã«ãŒããåé€ããããšãããšãã®èŠåã®äŸ
ãªãã©ã³ã¹ããªã«ããªãååæã®åéã§ãå€ãã®äœæ¥ãè¡ãããŠããŸãã çŸåšãvSANã¯ãã·ã¹ãã å
ã®ããããã®ããã€ã¹ã§80ïŒ
ã¬ãã«ã®ãªãœãŒã¹äœ¿çšçãéæããããšãITç°å¢ã®ãã©ã³ã¹ãèªåçã«å調æŽããŸãïŒãŸãã¯UIããå®è¡ã§ããŸãïŒã
埩å
ãšåæã®éã®ã·ã¹ãã æé ã¯æ¬¡ã®ãšããã§ãã ããšãã°ããã¹ãã70ã80ååŸã«è·åã«æ»ã£ãå ŽåãvSANã¯åªå
ãªãã·ã§ã³ã確èªããŸããçŸåšã®ã³ã³ããŒãã³ãã®åæ/埩å
ãç¶ç¶ããããåã«æŽæ°ããŸãã
vSANç°¡åã€ã³ã¹ããŒã«
ãªãªãŒã¹6.6ã§ã¯ãvSANã€ã³ãã©ã¹ãã©ã¯ãã£ã®æåã®å±éã«é©ããvCenter Server Applianceã®ã€ã³ã¹ããŒã©ãæ¹åãããŠããŸãã ããã«ãããæå®ãããESXiãã¹ãã䜿çšããŠåäžã®vSANã¯ã©ã¹ã¿ãŒãäœæãããŸãã
ã€ã³ã¹ããŒã«ãã§ãŒãºãšããŠvSANã¯ã©ã¹ã¿ãŒãäœæããããã®ç»é¢
vSAN Config Assist / Firmware Updatesåºæã®ããã»ã¹ã¯ããããã¯ãŒã¯ã®æºåãªã©ãããŸããŸãªäŸ¿å©ãªæ©èœãå®è¡ã§ããŸãããŸããå¿
èŠãªãªãã·ã§ã³ãŸãã¯æåŸ
ããããªãã·ã§ã³ããã¹ãŠã¢ã¯ãã£ãåãããæ£ããæ§æãããŠãããã©ããã確èªã§ããŸãã
æŽæ°ãªãã·ã§ã³ã¯ãOEMãœãããŠã§ã¢ãšãã©ã€ããŒãããŠã³ããŒãããŠæŽæ°ããŸãã çŸåšããã®ãªãã·ã§ã³ã¯ãDellãLenovoãFujitsuãããã³SuperMicro補åã«å®è£
ãããŠããŸãã
vSANã€ã³ãã©ã¹ãã©ã¯ãã£ãæ§ç¯ããããã®å¯èœãªãªãã·ã§ã³
VSAN Cloud Health Checkã¯ã䜿ãããããåäžãããããã«ããã€ãã®å€æŽãå ããŸããã
ããã©ãŒãã³ã¹ã¢ãã¿ãªã³ã°ã«ã¯ãvSANãååæãiSCSIãã¯ã©ã€ã¢ã³ããã£ãã·ã¥ãªã©ã®ã¡ããªãã¯ãå«ãŸããŸãã
Cloud Health Check and Analyticsã¯åé¡ãæ€åºãããã®æ°ãåžžã«å¢å ããŠããç¹å®ã®ãã¬ããžããŒã¹ïŒKBïŒãšé¢é£ä»ããŸãã
çµè«ãšããŠã以åã¯äž»ã«vSphereã«é©çšãããŠãããã«ã¹ã¿ããŒãšã¯ã¹ããªãšã³ã¹åäžããã°ã©ã ããæ¡åŒµãããããšãè¿œå ããå¿
èŠããããŸãã çŸåšãåºç¯ãªvSANæ
å ±ãå«ãŸããŠããããã©ãã«ã·ã¥ãŒãã£ã³ã°ã容æã«ãªããŸãã